CVG
Control Valve Group
Proportional, Load Sensing
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Catalogue HY11-3353/UK
Note
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS
DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL IN-
JURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiar-
ies and authorized distributors provide product or system options for further investiga-
tion by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the fi-
nal selection of the system and components and assuring that all performance, endur-
ance, maintenance, safety and warning requirements of the application are met. The
user must analyze all aspects of the application, follow applicable industry standards,
and follow the information concerning the product in the current product catalog and in
any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide compo-
nent or system options based upon data or specifications provided by the user, the
user is responsible for determining that such data and specifications are suitable and
sufficient for all applications and reasonably foreseeable uses of the components or
systems.
3
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Contents
Description Page
Introduction 4
General description, applications, benefits 4
Operation 5
Technical data 6
Ordering code 7
How to order CVG – CVG master code 7
Inlet section 8
Control section 9
Outlet section 10
Adapter section 11
Measuring data CVG 12
Pressure drop CVG compensator spools 12
Measuring data CVG30 13
Pressure drop CVG 30 spools 13
Compensator adjustment range CVG30 13
Measuring data CVG50 14
Pressure drop CVG 50 spools 14
Compensator adjustment range CVG50 14
Measuring data CVG60 15
Pressure drop CVG60 spools 15
Compensator adjustment range CVG60 15
Spool Selection Table 16
Standard spools 16
Meter out spools 16
Assembly Diagrams 17
CVG33 assembly example 17
Hydraulic diagram CVG33 17
CVG53 assembly example 18
Hydraulic diagram CVG53 18
CVG63 assembly example 19
Hydraulic diagram CVG63 19
Dimensions CVG30 20
Inlet section connections 20
Outlet section connections 20
Assembly, dimensions 21
Control section connections 21
Dimensions CVG50 22
Inlet section connections 22
Outlet section connections 22
Assembly, dimensions 23
Control section connections 23
Dimensions CVG60 24
Inlet section connections 24
Outlet section connections 24
Assembly, dimensions 25
Control section connections 25
Spare Parts 26
CVG30 control section 26
CVG50 control section 27
CVG60 control section 28
CVG30 inlet section with pressure relief 29
CVG50 inlet section with pressure relief 30
CVG60 inlet section with pressure relief 31
Adapters 32
4
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Introduction
General description
The CVG (Control Valve Group) is a compact load-
sensing valve assembly consisting of multiple direction-
al valve sections. Each control section has its own com-
pensator, so that speed control of multiple sections is
achieved, regardless of changes in pressure. The com-
pensator limits the maximum flow of control section and
it can be adjusted. Each control section has pressure
limiting valves in work ports. If load exceeds the setting,
the control section starts to reduce flow. The control sec-
tion keeps flow steady with different main spool opening
if pressure changes.
The design of the CVG is modular. There are three nom-
inal sizes of control sections available: CVG30, CVG50
and CVG60. Different sizes can be fitted together with
adapters. The nominal size determines the port sizes
and compensators flow range. Specific flow range is se-
lected by a main spool in each control section. The in-
let section has an option for a main pressure relief valve
and a pilot oil reducing valve for electrically controlled
CVG. The outlet section has also ports P and T to en-
sure full flow for control sections.
The main spool of control section can be operated pro-
portionally with hydraulic remote or electrically in an
open loop and also in a closed loop depending on op-
tion.
Applications
A CVG can be used to control wide range of machines
like cranes, large mobile vehicles, lifting equipment, drill-
ing equipment and stationary applications. High flows
can be accurately controlled with low pressure drop and
low hysteresis.
Benefits
Excellent machine controllability – individual pres-
sure compensation in each work section delivers pre-
dictable metering with single and multi-function oper-
ation, regardless of changes in pressure or input flow.
The maximum work pressure can be limited individually
in each work port. This enhances machine control and
improves productivity. The CVG has excellent linearity,
repeatability and low hysteresis.
Flexible design – the modular CVG design enables the
machine designer to add or remove content to achieve
the machine requirements. Different nominal sizes, sev-
eral spools and a wide range of spool control options
provide wide range of possibilities where to build cus-
tomized assembly to meet the requirements.
Wide flow range – the CVG single control sections can
handle flow starting from 50LPM in nominal size CVG30
ending up to 2000 LPM in CVG60. Inlet and outlet can
handle pump input up to 10 000LPM in CVG60.
Energy-efficient – high level controllability and efficien-
cy can be achieved by choosing the right spool size from
different nominal sizes. CVG can handle load pressure
up to 420 bar. With right system design this gives pos-
sibility to reduce oil flow and still have same power sup-
plied through the valve.
Factory tested – every CVG valve assemblies are test-
ed and adjusted before sending to the customer. This
reduces start up time and reduces risk of system fail-
ure. Customer individual features can be fully tested be-
fore start up.
Ease of service – the components of CVG are easily
changed without removing CVG from the system. Com-
pensator, pressure limiting valves and load-sensing
check valve are located on the top of each controls sec-
tion making it a service friendly design. Spare parts are
available worldwide from Parker.
5
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Introduction
Operation
Speed and direction movements of actuators are pro-
portionally controlled by spring centered main spools.
The pilot pressure moves the main spool against spring
force. In the electric version pilot pressure is adjusted by
electro-proportional 3-way pressure reduction valves. In
the hydraulic version the pilot pressure is adjusted by an
external control valve. The pilot oil flow to electro-pro-
portional pilot valves is supplied either internally or ex-
ternally. The internal signal is taken from port P through
a pressure reducing valve in the inlet section.
The pressure difference over main spool is kept constant
by a 2-way pressure compensator. Flow (and speed of
actuator) with certain opening of the main spool is con-
stant independent of load variations. Pressure compen-
sators are equipped with adjustable springs. The spring
force sets also a limit for maximum flow (speed of actua-
tor). Maximum feeding pressures in work ports A and B
are adjusted separately. When pressure exceeds setting
of the pilot valve, the pressure compensator starts to act
like a pressure reducing valve.
The CVG is a load sensing valve group. Every main
spool is equipped with LS signal channels. The highest
load pressure in the system is always connected to the
LS port in the inlet section. This signal can be used to
control a variable displacement pump. A CVG can be
used with fixed displacement pumps when the inlet sec-
tion is equipped with a 3-way pressure compensator.
When the system pressure exceeds the setting of the
pilot valve of the 3-way compensator, it starts to act like
a pressure relief valve.
In the open loop version, the position of the main spool
follows electric control signal coming from the amplifi-
er card. The main spool can be equipped with a position
sensor to read the movement of the main spool. In close
loop control with electro-proportional control version,
the position signal is sent to the amplifier card that com-
pares position signal to command signal and corrects
the control signal to solenoids accordingly. When hav-
ing close loop control option in CVG, the electro propor-
tional control end of spool is replaced with the close loop
control valve end. It has onboard electronics to compare
spool position to command signal and needs only power
supply and command signal for the main spool position.
General
Design Control valve group with modular design
Mounting positions Optional
Ambient temperature [°C] -30 ... +70
Hydraulic
Operating pressure [bar] 350, peak pressure 420
Fluid Mineral oil in accordance with DIN51524 and DIN51525
Fluid temperature [°C] -20 ... +90
Viscosity permitted [cSt] /
Viscosity recommended [cSt] /
[mm²/s]
[mm²/s]
15 … 380
30 … 80
Filtration ISO4406 (1999); 18/16/13
Leakage at 40 cSt [l/min] Up to 3 with 350 bar, depending on spool
Pilot pressure [bar]
Internally 45, externally to port PP2 through pressure reducing valve 45-420
should be 45-350 supply to port PP2 for pressure reducing valve
Max. pilot pressure 100
Hydraulic pilot [bar] External remote control for spool 0 - 35
Tank line [bar] Port T maximum pressure 30
Drain pressure [bar] Port DR maximum pressure 1
Nominal flow Flow with 5 bar pressure drop over one control edge of main spool
CVG30 CVG50 CVG60
[l/min] 500 / section 800 / section 1200 / section
Maximum flow [l/min] 750 / section 1200 / section 2000 / section
Main pressure relief Maximum flow of single* pressure relief valve
CVG30 Inlet section CVG50 inlet section CVG60 inlet section
[l/min] 400
Parker A06G2PZN
1200
Parker Lokomec CEL40
1200
Parker Lokomec CEL40
Static / Dynamic
Step response [ms] Open loop step response 0 to 100 %
CVG30 CVG50 CVG60
300 600 600
Closed loop control with onboard electronics <150 ms. Consult factory.
Electrical characteristic
Duty cycle [%] 100
Amplifier Parker IQAN control systems or Parker amplifiers for proportional valves
Protection class IP65
Current [mA] For spool control 0-800 mA (spool movement 300 - 750 mA)
Solenoid connection AMP Junior-Power-Timer (optional Deutsch DT04-2P connector)
ATEX solenoids Consult factory
Surface treatment
Painting 2-component epoxy primer RAL7004
*Outlet section can be equipped with secondary pressure relief. Adjustment is 10 bar higher than inlet pressure relief valve.
6
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Technical Data
2
3
4
5
6
1
7
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Code Description
CVG Control valve group
Code Description
3 CVG30
5 CVG50
6 CVG60
Code Description
3 CVG30
5 CVG50
6 CVG60
Code Description
Number of control sections
Code Description
Number of control sections
Ordering Code
How to order CVG
CVG master code
CVG
Example: CVG-51-32
Inlet with pressure relief valve and pilot oil pressure
reducing valve. One CVG50 control section with electro-
proportional pilot cover. Adapter to fit two CVG30 control
sections and outlet with ports P and T.
Adjustment values
Pressure and flow adjustment values of CVG assembly
are added after each part item code. Pressure setting
of main pressure relief is added after inlet section code.
Flow and pressure settings of A and B port is added after
control section code.
Qxx = maximum flow setting
Axx = maximum supply pressure of port A
Bxx = maximum supply pressure of port B
CVG-51-32 specific order code with pressure and
flow settings
1)
.
1. P50-21-BN2 350
2. S50-81-08-C1-00-F0-BN2 Q800 A350 B280
3. A530-BN2
4. S30-81-05-C1-00-F0-BN2 Q600 A350 B280
5. S30-31-03-C1-00-F0-BN2 Q450 A280 B280
6. T30-12-BN
1)
See specified coding for inlet, control and outlet section from ordering code pages.
(Additional stages)
8
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Ordering Code
Code Inlet section size
30 CVG30
50 CVG50
60 CVG60
Inlet section
P
B
Inlet
section
Seal
type
Design
B
Inlet
section
size
Pressure
relief valve
Pilot oil
pressure
reducing
valve
Measuring
connector
Code Pressure relief valve
1 Without pressure relief valve
2 With pressure relief valve
Code Pilot oil pressure reducing valve
1 With pilot oil pressure reducing valve,
internal supply
2 No pilot oil pressure reducing valve,
external supply from port PP
3 With pilot oil pressure reducing valve,
external supply from port PP2
Code Seal type
N NBR
V FPM
Code Pressure measuring connector type
2 Carbon steel connector
3 Stainless steel connector
9
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Ordering Code
Code Control section size
30 CVG30
50 CVG50
60 CVG60
Code Spool size
00 50 l/min (size 30)
01 150 l/min (size 30)
02 200 l/min (size 30)
05 500 l/min (size 30)
08 800 l/min (size 50)
10 1000 l/min (size 50/60)
12 1200 l/min (size 60)
Code Pilot control cover (A side)
C1 Electro-proportional
C2
Electro-proportional and
external hydraulic pilot
C3 External hydraulic pilot
C4
Electro-proportional high
step response
C5
Electro-proportional high
step response and external
hydraulic pilot
C6
Closed loop with onboard
electronics
E1 Electro-proportional ATEX
E2
Electro-proportional ATEX and
external hydraulic pilot
E4
Electro-proportional high
step response ATEX
Control section
Control
section
Measuring
connector
Control
section
size
Seals
Spool
option
Spool
cover
Spool
size
Design
Pilot
control
cover
Adapter Adapter
Code Adapter in port A
0 No adapter
1
2x 1 ½” SAE62
(CVG50, CVG60)
2
2x 2” SAE62
(CVG60)
Code
Measuring
connector type
2
Carbon steel
connectors
3
Stainless steel
connectors
S B
Code Drawing Spool option
31
Spool 03, symmetric
32 Spool 03, meter out
81 Spool 08, symmetric
82 Spool 08, meter out
XX Specially designed spool
1)
Code Seals type
N NBR
V FPM
Code Spool Cover (B side)
F0 No feedback
F1
Spool position
feedback LVDT
2)
Code Adapter in port B
0 No adapter
1
2x 1 ½" SAE62
(CVG50, CVG60)
2
2x 2" SAE62
(CVG60)
1)
Please consult Parker.
2)
Please consult Parker for different types of LVDT sensors.
10
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Ordering Code
Outlet
section
Outlet
section
size
Pressure
relief
valve
Pilot
oil
Design
Seal
T 2 B
Code Outlet section size
3 CVG30
5 CVG50
6 CVG60
Code Pressure relief valve
0
Blind plate.
No connections
1
Without pressure relief.
Connections P and T
2
With pressure
relief valve.
Connections P and T
Code
Pilot oil pressure
reducing valve
2
Without pilot oil pres-
sure reducing valve
Code Seal type
N NBR
V FPM
Outlet section
11
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Ordering Code
Adapter
section
Inlet
section
Design
Extra
ports
Seal
A B
Code Inlet section size
330 CVG30 to CVG30
530 CVG50 to CVG30
630 CVG60 to CVG30
650 CVG60 to CVG50
550 CVG50 to CVG50
Code Extra ports
1 No ports
2 Extra ports P, T
Code Seal type
N NBR
V FPM
Adapter section
12
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Measuring Data CVG
Pressure drop CVG compensator spools
The pressure difference over compensator is measured
when compensator spool is forced fully open. Pressure
is measured from ports MP and M1. Total pressure loss
over control section is sum of compensator spool pres-
sure loss and main spool pressure loss.
Measured with HLP46 at 50 °C
CVG50/60 step response
CVG30 spool opening vs current CVG30 step response
CVG50/60 spool opening vs current
13
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Measuring Data CVG30
Pressure drop CVG30 spools
The diagram below specifies the pressure loss over spool control edge.
Compensator adjustment range CVG30
The diagram specifies the control curves for spool “81-05”* with different compensator settings.
spool nominal size
Position b Position a
P-B A-T P-A B-T
00 50 l/min (size 30) 1 1 1 1
01 150 l/min (size 30) 2 2 2 2
02 200 l/min (size 30) 3 3 3 3
05 500 l/min (size 30) 4 4 4 4
* For adjustment range for other spools, please consult Parker.
All characteristic curves measured with HLP46 at 50 °C
14
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Measuring Data CVG50
Pressure drop CVG 50 spools
The diagram below specifies the pressure loss over spool control edge.
Compensator adjustment range CVG50
The diagram shows the control curves for spool “81-08*”
with different compensator settings.
open
4 turns
6 turns
2 turns
Compensator bolt
8 turns
0
0 500
Current [mA]
Flow [l/min]
400300200100 600 800700
1400
1200
1000
800
600
400
200
9.5 turns
spool nominal size
Position b Position a
P-B A-T P-A B-T
08 800 l/min (size 50) 1 1 1 1
10 1000 l/min (size 50) 2 2 2 2
All characteristic curves measured with HLP46 at 50 °C
600
400
200
0
0 500
Current [mA]
Flow [l/min]
400300200100 600 800700
1800
1600
1400
1200
1000
800
2 turns
4 turns
max.
open
6 turns
8 turns
Compensator bolt
The diagram shows the control curves for spool “81-10”*
with different compensator settings.
* For adjustment range for other spools, please consult Parker.
15
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Measuring Data CVG60
Pressure drop CVG60 spools
The diagram below specifies the pressure loss over spool control edge.
Compensator adjustment range CVG60
The diagram shows the control curves for spool “81-12”* with different compensator settings.
spool nominal size
Position b Position a
P-B A-T P-A B-T
10 1000 l/min (size 60) 1 1 1 1
12 1200 l/min (size 60) 2 2 2 2
All characteristic curves measured with HLP46 at 50 °C
* For adjustment range for other spools, please consult Parker.
16
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
CVG size Code Nominal flow*
Recommended
compensator adjust-
ment range [l/min]
Function
Spool assembly
part number
Spool part
number
CVG30 81-00 60 70 - 110 open center, symmetric 31008702 31013300
CVG30 31-00 60 70 - 110 closed center, symmetric 31008705 31014400
CVG30 81-01 140 130 - 220 open center, symmetric 31008713 31131200
CVG30 31-01 140 130 - 220 closed center, symmetric 31008719 31172100
CVG30 81-02 220 220 - 370 open center, symmetric 31008701 31013200
CVG30 31-02 220 220 - 370 closed center, symmetric 31008704 31014500
CVG30 81-05 500 360 - 750 open center, symmetric 31008700 31011500
CVG30 31-05 500 360 - 750 closed center, symmetric 31008703 31014600
CVG50 81-08 820 600 - 1200 open center, symmetric 31012801 39721200
CVG50 31-08 820 600 - 1200 closed center, symmetric 31012804 31043800
CVG50 81-10 1000 700 - 1400 open center, symmetric 31012800 39721000
CVG50 31-10 1000 700 - 1400 closed center, symmetric 31012803 31036800
CVG60 81-10 950 800 - 1500 open center, symmetric 31012801 39721200
CVG60 31-10 950 800 - 1500 closed center, symmetric 31012804 31043800
CVG60 81-12 1150 1000 - 2000 open center, symmetric 31012800 39721000
CVG60 31-12 1150 1000 - 2000 closed center, symmetric 31012803 31036800
Spool Selection Table
CVG-B spool table
Standard spools
* l/min at 5 bar over one control edge measured from M1 and MA. Accuracy ± 2 %.
CVG size Code Nominal flow*
Recommended
compensator adjust-
ment range [l/min]
Function
Spool assembly
part number
Spool part
number
CVG30 32-02 220 215 - 370 closed center, A-T meter-out 25 % 31008707 31068300
CVG30 32-05 500 360 - 750 closed center, A-T meter-out 25 % 31008706 31063500
CVG50 82-10 1000 700 - 1400 open center, A-T meter-out 25 % 31012808 31086000
CVG50 32-10 1000 700 - 1400 closed center, A-T meter-out 25 % 31012806 31049800
CVG60 82-12 1150 1000 - 2000 open center, A-T meter-out 25 % 31012808 31086000
CVG60 32-12 1150 1000 - 2000 closed center, A-T meter-out 25 % 31012806 31049800
Meter out spools
17
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
CVG33 assembly example
Assembly Diagrams
The CVG33 assembly includes the inlet section, three
control sections and the outlet section. Here is shown one
variation of CVG33 assembly with three different types
of control sections. The same assembly is shown in the
dimensional section of this catalogue.
1 P30-21-BN2
Inlet section with pressure relief and pilot pressure
valve
2 S30-81-05-C1-00-F0-BN2
Section 1 with electronic spool pilot
3 S30-81-05-C2-00-F0-BN2
Section 2 with electronic and hydraulic spool pilot
4 S30-31-05-C3-00-F1-BN2
Section 3 with hydraulic spool pilot and spool position
sensor
5 T30-22-BN
Outlet section with pressure relief
Hydraulic diagram CVG33
1 2 3 4 5
G
PP
MPP
PP2
MDR
DR
T
MT
MP
P
MLS
LS
PP
P
DR
T
LS
A
MA MB
B
MPB
ba
MC
MLAMLB
M1
PP
P
DR
T
LS
A
MA MB
B
PP
P
DR
T
LS
ba
MC
PB
MLAMLB MPA
M1
PA
MPBMPA
T
PP
P
P
DR
T
LS
A
MC
PB
MLAMAMBMPA
M1
PAB
MPBMLB
A
P
B
T
AB
PT
AB
PT
U
18
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
1 2 3 4 5
T
P
G
PP
MPP
PP2
MDR
DR
T
MT
MP
P
MLS
LS
PP
P
DR
T
LS
ba
MC M1
PP
P
DR
T
LS
T
PP
P
P
DR
T
LS
MC M1
A
P
B
T
AB
PT
AB
PT
MC M1
AB
PT
PP
P
DR
T
LS
ba
G
U
MPB MLAMLB MPA
A2 A1 B1 B2
MAMPB MLAMLB MPAMB
PB PAAB
MAMPB
MLA
MLBMB
PB A
MPA
PA
CVG53 assembly example
Assembly Diagrams
The CVG53 assembly includes the inlet section, three
control sections and the outlet section. Here is shown one
variation of CVG53 assembly with three different types
of control sections. The same assembly is shown in the
dimensional section of this catalogue.
1 P50-21-BN2
Inlet section with pressure relief and pilot pressure
valve
2 S50-81-08-C1-11-F0-BN2
Section 1 with electronic spool pilot
3 S50-81-08-C2-00-F0-BN2
Section 2 with electronic and hydraulic spool pilot
4 S50-31-08-C3-00-F1-BN2
Section 3 with hydraulic spool pilot and spool position
sensor
5 T50-12-BN
Outlet section without pressure relief
Hydraulic diagram CVG53
19
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
CVG63 assembly example
Assembly Diagrams
The CVG63 assembly includes the inlet section, three
control sections and the outlet section. Here is shown one
variation of CVG63 assembly with three different types
of control sections. The same assembly is shown in the
dimensional section of this catalogue.
1 P60-21-BN
Inlet section with pressure relief and pilot pressure
valve
2 S60-81-08-C1-22-F0-BN2
Section 1 with electronic spool pilot
3 S60-81-08-C2-11-F0-BN2
Section 2 with electronic and hydraulic spool pilot
4 S60-31-08-C3-00-F1-BN2
Section 3 with hydraulic spool pilot and spool position
sensor
5 T60-22-BN
Outlet section with pressure relief
Hydraulic diagram CVG63
G
ba
MC M1
PP
P
DR
T
LS
T
PP
P
P
DR
T
LS
MC M1
A
P
B
T
AB
PT
AB
PT
PP
MPP
PP2
MDR
DR
T
MT
P
P
MLS
LS
PP
P
DR
T
LS
ba
MP
PP
P
DR
T
LS
MC M1
P
G
U
MAMPBMLA MLBMPA
MB
A2 A1 B1 B2
MAMPBMLA MLBMPAMB
PB PA
MAMPB
MLA
MLBMB
PB A
MPA
PA
A2 B1 B2 A2 A1 B1 B2
B
1 2 3 4 5
20
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
175
121.5
62
14.5
0
13
37.537.537.5
20
368.8
145
71
0
121.5
37.5
59
16
42
41
85
L2
L
0
21.5
81
162
221.5
4xM16/20
145
71
45
39
0
52
Assembly label
Secondary pressure relief
Main pressure relief valve
Cover C1
Cover C2
Cover C3
Outlet section connections
P, T G 1 ½" BSPP
P, T G 1 ½" BSPP
DR G " BSPP
LS, PP, PP2 G ¼" BSPP
MP, MT, MLS, MPP, MDR G ¼" BSPP
Inlet section connections
D1 D2 D3 L1
G ⅛" 8.8 20 10
G ¼" 11.8 25 14
G " 15.25 29 14
G ½" 19 34 16
G ¾" 24.5 42 18
G 1" 30.5 47 20
G 1 ¼" 39.5 58 22
G 1 ½" 45 65 24
G 2" 57 76 29
ISO 228 - G BSPP threads
Dimensions CVG30
21
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Cover F1
Cover F0
Cover F0
185
142.6
150.5 243 66.5
0
75
150
225
300
375
Pilot pressure valve
Pos. Name Code
Weight
(kg)
1 Inlet section P30-21-BN2 21
2 Control section S30-81-05-C1-00-F0-BN2 38
3 Control section S30-81-05-C2-00-F0-BN2 38
4 Control section S30-31-05-C3-00-F1-BN2 38
5 Outlet section T30-22-BN 22
Assembly
Control section connections
A, B G 1 ½" BSPP
MPA, MPB G ¼" BSPP
MLA, MLB, M1 G ¼" BSPP
PA, PB (Cover C2 and C3) G ¼" BSPP
Dimensions
No. of control
sections
L
(mm)
L2
(mm)
Weight (kg)
1 225 185 81
2 300 260 119
3 375 295 157
4 450 330 195
5 525 365 233
Dimensions CVG30
22
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Assembly label
138
0
67
191
4x M20/30
105
91
50
0
0
25
50
216
225
Cover C3
Cover C2
Cover C1
L2
L
50
60606070
Adapter 1
13.5
0
23
87.5
188.5
253
289.5
60
105
60
98
118
487
191
67
0
138
Dimensions CVG50
1 1/2" SAE62
79.38
36.53
M16/25
ø14/30
ø40/
2 1/2" SAE61
89
50.8
M12/16
ø10.2/21
ø60/
2" SAE62
44.45
96.82
M20/35
ø17.5/42
ø48/
D1 D2 D3 L1
G ⅛" 8.8 20 10
G ¼" 11.8 25 14
G " 15.25 29 14
G ½" 19 34 16
G ¾" 24.5 42 18
G 1" 30.5 47 20
G 1 ¼" 39.5 58 22
G 1 ½" 45 65 24
G 2" 57 76 29
ISO 228 - G BSPP threads
Inlet section connections
P 2" SAE62
T 2 ½" SAE61
DR G ½" BSPP
LS, PP, PP2 G " BSPP
MP, MT, MLS, MPP, MDR G ¼" BSPP
Outlet section connections
P 2 SAE62
T 2 ½ SAE61
23
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
5
4
3
2
1
Cover F1
Cover F0
Cover F0
Main pressure relief valve
260 65
600
480
360
240
120
0
168.8
Pilot pressure valve
276 97.3
143.6
73.3
Pos. Name Code
Weight
(kg)
1 Inlet section P50-21-BN2 58
2 Control section S50-81-08-C1-11-F0-BN2 81
3 Control section S50-81-08-C2-00-F0-BN2 81
4 Control section S50-31-08-C3-00-F1-BN2 81
5 Outlet section T50-12-BN 54
Assembly Dimensions
No. of control
sections
L
(mm)
L2
(mm)
Weight
(kg)
1 220 360 193
2 340 480 274
3 460 600 355
4 580 720 436
5 700 840 517
Control section connections
A, B 1 ½" SAE62
MPA, MPB G ¼" BSPP
MLA, MLB, M1 G ¼" BSPP
PA, PB (Cover C2 and C3) G ¼" BSPP
Dimensions CVG50
24
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Assembly label
69
138
207
0
0
88
213
Cover C3
Cover C2
Cover C1
L2
L
7070
707070
118
115
70
108
70
Adapter 1
Adapter 2
533
213
88
0
0
69
138
207
41
32
0
76
79
197
200
253
308
317
23
4x M20/30
Dimensions CVG60
Inlet section connections
Outlet section connections
P 2x 2" SAE62
T 3" SAE61
DR G ½" BSPP
LS, PP, PP2 G ⅜" BSPP
MP, MT, MLS, MPP, MDR G ¼" BSPP
P 2x 2" SAE62
T 3" SAE61
D1 D2 D3 L1
G ⅛" 8.8 20 10
G ¼" 11.8 25 14
G " 15.25 29 14
G ½" 19 34 16
G ¾" 24.5 42 18
G 1" 30.5 47 20
G 1 ¼" 39.5 58 22
G 1 ½" 45 65 24
G 2" 57 76 29
ISO 228 - G BSPP threads
25
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
700
560
420
280
140
0
Secondary pressure relief
5
4
3
2
1
Main pressure relief
Cover F0
Cover F0
Cover F1
143.6
73.3
168.8 276
77
99
Pilot pressure valve
Assembly
Control section connections
Pos. Name Code Weight
1 Inlet section P60-21-BN2 79
2 Control section S60-81-10-C1-22-F0-BN2 135
3 Control section S60-81-10-C2-11-F0-BN2 131
4 Control section S60-31-10-C3-00-F1-BN2 97
5 Outlet section T60-22-BN 54
A, B 2" SAE62
MPA, MPB G ¼" BSPP
MLA, MLB, M1 G ¼" BSPP
PA, PB (Cover C2 and C3) G ¼" BSPP
Dimensions
No. of control
sections
L
(mm)
L2
(mm)
Weight
(kg)
1 280 420 250
2 420 560 347
3 560 700 444
4 700 840 541
5 840 980 638
Dimensions CVG60
26
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
Position
110829XX
Quantity
Code Type
1 TS110829 SEAL KIT 110829
2 31013500 CVG30 PILOT COVER ASSEMBLY C1 1
2 31013502 CVG30 PILOT COVER ASSEMBLY C2 1
2 31013502 CVG30 PILOT COVER ASSEMBLY C3 1
3 31013600 CVG30 COVER ASSEMBLY F0 1
4 310087XX CVG30 SPOOL ASSEMBLY 1
5 31013400 CVG30 COMPENSATOR ASSEMBLY 1
6 PRPA1017 A04G2PZN + CAP 410312 2
7 K02A3N K02A3N 1
8 VAHA0011 RK1 CHECK VALVE 1
9 KU005200 M5X5-2,0 2
10 PAMA0410 TM85201 24VDC32BAR FILT+OVER 2
11 LVDT ASSEMBLY 1
12 SF438064 SPRING FOR SPOOL 1
13 SF426127 SPRING FOR COMPENSATOR 1
14 41006800 COMPENSATOR SPOOL 1
15 KU006060 M6X6-0,6 1
16 MISTG142 SMK 20-G1/4-VC-V2A<1,4305>AI 8
CVG30 control section
27
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
Position
110842XX
Quantity
Code Type
1 TS110842 SEAL KIT 110842 1
2 31013100 CVG PILOT COVER ASSEMBLY C1 1
2 31013101 CVG PILOT COVER ASSEMBLY C2 1
2 31013102 CVG PILOT COVER ASSEMBLY C3 1
3 31013000 CVG COVER ASSEMBLY F0 1
4 31012800 CVG SPOOL ASSEMBLY 1
5 31012900 CVG50 COMPENSATOR ASSEMBLY 1
6 PRPA1017 A04G2PZN + CAP 410312 2
7 K02A3N K02A3N 1
8 VAHA0011 RK1 CHECK VALVE 1
9 KU005200 M5X5-2,0 2
10 PAMA0410 TM85201 24VDC32BAR FILT+OVER 2
11 LVDT ASSEMBLY 1
12 SF451001 SPRING FOR SPOOL 1
13 SF432000 SPRING FOR COMPENSATOR 1
14 44289400 COMPENSATOR SPOOL 1
15 KU006080 M6X6-0,8 1
16 EMA3/1/4EDBPCF EMA3/1/4EDBPCF 8
CVG50 control section
28
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
Position
110734XX
Quantity
Code Type
1 TS 110734 SEAL KIT 110734
2 31013100 CVG PILOT COVER ASSEMBLY C1 1
2 31013101 CVG PILOT COVER ASSEMBLY C2 1
2 31013102 CVG PILOT COVER ASSEMBLY C3 1
3 31013000 CVG COVER ASSEMBLY F0 1
4 31012800 CVG SPOOL ASSEMBLY 1
5 31178700 CVG60 COMPENSATOR ASSEMBLY 1
6 PRPA1017 A04G2PZN + CAP 410312 2
7 K02A3N K02A3N 1
8 VAHA0011 RK1 CHECK VALVE 1
9 KU005200 M5X5-2,0 2
10 PAMA0410 TM85201 24VDC32BAR FILT+OVER 2
11 LVDT ASSEMBLY 1
12 SF451001 SPRING FOR SPOOL 1
13 SF432000 SPRING FOR COMPENSATOR 1
14 44289400 COMPENSATOR SPOOL 1
15 KU006080 M6X6-0,8 1
16 EMA3/1/4EDBPCF EMA3/1/4EDBPCF 8
CVG60 control section
29
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
Position
211545XX
Quantity
Code Type
1 TS211545 SEAL KIT 211545 1
2 PRPA2505 A06G2PZN + CAP 410312 1
3 PAPA1038 C04B3HZN + CAP 410312 1
4 KU006040 M6X6-0,4
5 EMA3/1/4EDBPCF EMA3/1/4EDBPCF 5
CVG30 Inlet section with pressure relief
30
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Position
211080XX
Quantity
Code Type
1 TS211080 SEAL KIT 211080 1
2 31156900 CRL40 R6S AN X12C10 1
3 41003802 CEL40 A40 AN 00 1
4 PAPA1038 C04B3HZN + CAP 410312 1
5 KU006040 M6X6-0,4 1
6 EMA3/1/4EDBPCF EMA3/1/4EDBPCF 5
Spare Parts
CVG50 Inlet section with pressure relief
31
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
Position
210938XX
Quantity
Code Type
1 TS210938 SEAL KIT 210938 1
2 31156900 CRL40 R6S AN X12C10 1
3 41003802 CEL40 A40 AN 00 1
4 PAPA1038 C04B3HZN + CAP 410312 1
5 KU006040 M6X6-0,4 1
6 EMA3/1/4EDBPCF EMA3/1/4EDBPCF 5
CVG60 Inlet section with pressure relief
4
5
6
3
2
32
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Spare Parts
211350XX Adapter A650 1
1 TS211350 SEAL KIT 211350
211351XX Adapter A530 1
1 TS211351 SEAL KIT 211351
111198XX Adapter A630 1
1 TS111198 SEAL KIT 111198
1
1
1
Adapters
33
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Notes
34
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Notes
35
Catalogue HY11-3353/UK
HY11-3353 CVG UK.indd CM 07.10.13
Parker Hannifin Corporation
Hydraulics Group
Mobile Directional Control Valve
CVG
Notes
Your local authorized Parker distributor
EMEA Product Information Centre
Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL,
IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)
US Product Information Centre
Toll-free number: 1-800-27 27 537
www.parker.com
Parker Worldwide
Europe, Middle East, Africa
AE – United Arab Emirates,
Dubai
Tel: +971 4 8127100
parker.me@parker.com
AT – Austria, Wiener Neustadt
Tel: +43 (0)2622 23501-0
parker.austria@parker.com
AT – Eastern Europe, Wiener
Neustadt
Tel: +43 (0)2622 23501 900
parker.easteurope@parker.com
AZ – Azerbaijan, Baku
Tel: +994 50 22 33 458
parker.azerbaijan@parker.com
BE/LU – Belgium, Nivelles
Tel: +32 (0)67 280 900
parker.belgium@parker.com
BG – Bulgaria, Soa
Tel: +359 2 980 1344
parker.bulgaria@parker.com
BY – Belarus, Minsk
Tel: +375 17 209 9399
parker.belarus@parker.com
CH – Switzerland, Etoy
Tel: +41 (0)21 821 87 00
parker.switzerland@parker.com
CZ – Czech Republic, Klecany
Tel: +420 284 083 111
parker.czechrepublic@parker.com
DE – Germany, Kaarst
Tel: +49 (0)2131 4016 0
parker.germany@parker.com
DK – Denmark, Ballerup
Tel: +45 43 56 04 00
parker.denmark@parker.com
ES – Spain, Madrid
Tel: +34 902 330 001
parker.spain@parker.com
FI – Finland, Vantaa
Tel: +358 (0)20 753 2500
parker.nland@parker.com
FR – France, Contamine s/Arve
Tel: +33 (0)4 50 25 80 25
parker.france@parker.com
GR – Greece, Athens
Tel: +30 210 933 6450
parker.greece@parker.com
HU – Hungary, Budaoers
Tel: +36 23 885 470
parker.hungary@parker.com
IE – Ireland, Dublin
Tel: +353 (0)1 466 6370
parker.ireland@parker.com
IT – Italy, Corsico (MI)
Tel: +39 02 45 19 21
parker.italy@parker.com
KZ – Kazakhstan, Almaty
Tel: +7 7273 561 000
parker.easteurope@parker.com
NL – The Netherlands, Oldenzaal
Tel: +31 (0)541 585 000
parker.nl@parker.com
NO – Norway, Asker
Tel: +47 66 75 34 00
parker.norway@parker.com
PL – Poland, Warsaw
Tel: +48 (0)22 573 24 00
parker.poland@parker.com
PT – Portugal, Leca da Palmeira
Tel: +351 22 999 7360
parker.portugal@parker.com
RO – Romania, Bucharest
Tel: +40 21 252 1382
parker.romania@parker.com
RU – Russia, Moscow
Tel: +7 495 645-2156
parker.russia@parker.com
SE – Sweden, Spånga
Tel: +46 (0)8 59 79 50 00
parker.sweden@parker.com
SK – Slovakia, Banská Bystrica
Tel: +421 484 162 252
parker.slovakia@parker.com
SL – Slovenia, Novo Mesto
Tel: +386 7 337 6650
parker.slovenia@parker.com
TR – Turkey, Istanbul
Tel: +90 216 4997081
parker.turkey@parker.com
UA – Ukraine, Kiev
Tel +380 44 494 2731
parker.ukraine@parker.com
UK – United Kingdom, Warwick
Tel: +44 (0)1926 317 878
parker.uk@parker.com
ZA – South Africa, Kempton Park
Tel: +27 (0)11 961 0700
parker.southafrica@parker.com
North America
CA – Canada, Milton, Ontario
Tel: +1 905 693 3000
US – USA, Cleveland
(industrial)
Tel: +1 216 896 3000
US – USA, Elk Grove Village
(mobile)
Tel: +1 847 258 6200
Asia Pacific
AU – Australia, Castle Hill
Tel: +61 (0)2-9634 7777
CN – China, Shanghai
Tel: +86 21 2899 5000
HK – Hong Kong
Tel: +852 2428 8008
ID – Indonesia, Tangerang
Tel: +62 21 7588 1906
IN – India, Mumbai
Tel: +91 22 6513 7081-85
JP – Japan, Fujisawa
Tel: +81 (0)4 6635 3050
KR – South Korea, Seoul
Tel: +82 2 559 0400
MY – Malaysia, Shah Alam
Tel: +60 3 7849 0800
NZ – New Zealand, Mt Wellington
Tel: +64 9 574 1744
SG – Singapore
Tel: +65 6887 6300
TH – Thailand, Bangkok
Tel: +662 717 8140
TW – Taiwan, New Taipei City
Tel: +886 2 2298 8987
VN – Vietnam, Ho Chi Minh City
Tel: +84 8 3999 1600
South America
AR – Argentina, Buenos Aires
Tel: +54 3327 44 4129
BR – Brazil, Cachoeirinha RS
Tel: +55 51 3470 9144
CL – Chile, Santiago
Tel: +56 2 623 1216
MX – Mexico, Toluca
Tel: +52 72 2275 4200
Catalogue HY11-3353/UK, POD 09/2013, ZZ© 2013 Parker Hannin Corporation. All rights reserved.